<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-05 20-43-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 69 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.2 kHz 60 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 62 kHz 19100 0,4346
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 3,96 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 20:43, 5.05.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 62 kHz MIN: 10 kHz % above 76 kHz: 0,4346 Acquired: 2025/05/05 20.42.15 Total samples: 19100 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,2 dBr MIN: 2,3 dBr AVE: 3,96 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2025/05/05 20.42.14) 20.28 20.30 20.32 20.34 20.36 20.38 20.40 20.42 0 2 4 6 Pm [dBr]